Results

By using 50 model evaluations AutoCal finds a horizontal hydraulic conduc­tivity of 0.00199 [m/s].

Results from the optimisation can be found in the files Example1.dat and Example1_Optimisation.dat. Example1.dat shows the evaluated parameter (HHydrCond), output measure (MyOutput) and objective function (myFunc) for the different model runs in the optimisation. The last line is the optimum solution. Example_Optimisation.dat shows the population of parameter sets and corresponding objective functions for the different loops of the optimisa­tion sorted with respect to the aggregated objective function (in this case myFunc).