After 160 evaluations the objective function convergence criteria are met. AutoCal finds the following results:
Recharge = 10 [mm]
HHydrCond_layer1 = 0.00199 [m/s]
HHydrCond_layer2 = 0.00145 [m/s]
VHydrCond_layer1 does not appear in the results because it has been set to "Dependent" on HHydrCond_layer1.
Results from the optimisation can be found in the files Example2.dat and Example2_Optimisation.dat. Example2.dat shows the evaluated parameter (HHydrCond), output measure (Well) and objective function (myFunc) for the different model runs in the optimisation. The last line is the optimum solution. Example_Optimisation.dat shows the population of parameter sets and corresponding objective functions for the different loops of the optimisation sorted with respect to the aggregated objective function (in this case myFunc).