Under Simulation specifications, model simulation sequence, model parameter file(s) and simulation option must be specified.
In Example 1 the MIKE SHE setup (Example1.she) is selected for both model simulation sequence and model parameter file because besides producing results it also contains the parameter chosen for optimization. Once Example1.she has been specified as model parameter file, AutoCal will automatically produce a template MIKE SHE file called Example1_Autocal.she. Example1_Autocal.she is a copy of Example1.she which is then edited to mark the aquifer horizontal hydraulic conductivity for optimization. The horizontal hydraulic conductivity is given the value 1.01e-035.
Parameter Optimization is chosen as simulation option.