Under simulation specifications, model simulation sequence, model parameter file(s) and simulation option must be specified.
In Example 2 the MIKE SHE setup (Example2.she) is selected for both model simulation sequence and model parameter file because besides producing results it also contains the parameters chosen for optimization. Once Example2.she has been specified as model parameter file, AutoCal will automatically produce a template she file called Example2_Autocal.she. Example2_Autocal.she is a copy of Example2.she which is then edited to mark the parameters for optimization. Rainfall is given the value 1.01e-035, horizontal hydraulic conductivity of layer 1 is given the value 1.02e-035, vertical hydraulic conductivity of layer 1 is given the value 1.03e-035 and horizontal hydraulic conductivity of layer 2 is given the value 1.04e-035
Parameter Optimization is chosen as simulation option.