Output

If output is included you must specify the name of the output file. The file will, for each jet source, contain information of the calculated jet.

The output file contains the following seven items for each jet source:

1.       x end position - x-position when the jet/plume  becomes passive

2.       y end position - y-position when the jet/plume  becomes passive

3.       z end position - z-position when the jet/plume  becomes passive

4.       Characteristic width - diameter of the  of the jet/plume when it becomes passive

5.       Dilution factor - centerline dilution of a tracer or pollutant mass when the jet/plume becomes passive

6.       Distance - the distance in horizontal plane from the initial jet/plume posi­tion to the end position.

7.       Stop code - the stop code is an integer between  1 and 6 correspond to the six stop criteria listed in General description.