Data
The format of the initial conditions for temperature and salinity can be specified as:
· Constant (in domain)
· Varying in domain
For the case with varying in domain you have to prepare a data file containing the initial conditions (temperature or salinity) before you set up the hydrodynamic simulation.
In case of 2D simulation the file must be a 2D unstructured data file (dfsu) or a 2D grid data file (dfs2).
In case of 3D simulation the file must be a 3D unstructured data file (dfsu) or a 3D grid data file (dfs3).
The area in the data file must cover the model area. If a 2D dfsu-file is used, piecewice constant interpolation is used to map the data. If a 3D dfsu file is used, the mesh in the data file must match exactly the mesh in the simulation.If a dfs2-file or dfs3-file is used, bilinear interpolation is used to map the data. In case the input data file contains a single time step, this field is used. In case the file contains several time steps, e.g. from the results of a previous simulation, the actual starting time of the simulation is used to interpolate the field. Therefore the starting time must be within the start and end time of the file.