  NameDescription
Public propertyDescription
User's descriptive information related to the link
(Inherited from Reach.)
Public propertyEndConnection
Specifies where the reach is connected at its end point (high chainage). Must be null if not connected.
(Inherited from Reach.)
Public propertyIsPressureReach
True if the reach should always be pressurized (MU special reach with slope=0 and "weir" at transition to normal reach.)
(Inherited from Reach.)
Public propertyIsRegulatedReach
Regulate reach with a discharge structure on first q-grid point. This is used for MU setups to limit Q to a QMax(H) og QMax(dH). QMax is set by a control in the control module
(Inherited from Reach.)
Public propertyLocationSpan
The XYZ LocationSpan contains the reach ID, start and end chainages and digipoints in one structure.
(Inherited from Reach.)
Public propertyMaximumDx
The maximal allowed distance between two points of the same type?
(Inherited from Reach.)
Public propertyNonReturnReach
Restrict flow in the first q-grid point to be positive only. Default is false
(Inherited from Reach.)
Public propertyReverseDirection
Reverse the positive flow direction of the reach. Default is false
(Inherited from Reach.)
Public propertyRoutingElements
Routing elements used in this reach
Public propertyStartConnection
Specifies where the reach is connected at its start point (low chainage). Must be null if not connected.
(Inherited from Reach.)
Public propertyTopoID
Id for the cross section topologi that is to be used for the Link / Branch. If TopoID is not used, set to empty string (null will be handled as the empty string).
(Inherited from Reach.)