The setup used in Example 2 is a relatively simple MIKE SHE model including only the Saturated Zone (SZ), which is composed of three layers. Constant uniform precipitation is applied, rainfall completely infiltrates and two pumping wells are included in the SZ. See the setup for details.
The objective of the example is to calibrate the model with respect to horizontal and vertical hydraulic conductivities of layer 1, horizontal hydraulic conductivity of layer 2 and rainfall (recharge), given measured SZ head elevations in correspondence of the two pumping wells.
The example is included as Example2.auc. Two subfolders, called "Setup" and "Measurements", are present. The first one contains all the relevant files for the auto-calibration simulation while the second one includes all the measurements/observed data.
Simulation specifications
Model Parameters
Objective Functions
Parameter Optimisation
Save Output Files
Simultaneous simulations
Results