BridgeBaseUseFHWAReachLength Property |
The reach length for the FHWA method is determined based on an equal
conveyance tube analysis. if the reach length should only be based on
the physical distance from the adjacent cross section to the bridge
the variable 'USE_FHWA_REACH_LENGTH' may be used.
Namespace:
DHI.Mike1D.StructureModule
Assembly:
DHI.Mike1D.StructureModule (in DHI.Mike1D.StructureModule.dll) Version: 16.0.0.0 (11.1.1.1111)