| DischargeStructure Properties | 
The DischargeStructure type exposes the following members.
 Properties
Properties| Name | Description | |
|---|---|---|
|  | ActualDischarge | 
            Discharge for a single structure. 
             | 
|  | ControlledMaxDischarge | 
            Maximum limit on discharge controllable from outside.
            Only used if _useControlledMaxDischarge == true
             | 
|  | ControlledMinDischarge | 
            Minimum limit on discharge controllable from outside.
            Only used if _useControlledMinDischarge == true
             | 
|  | dDischargedDownStreamWaterLevel | 
            Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
            The value is calculated by SetWaterLevels.
            Unit: [m^2/s]
            (Inherited from Structure.) | 
|  | dDischargedUpStreamWaterLevel | 
            Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
            The value is calculated by SetWaterLevels.
            Unit: [m^2/s]
            (Inherited from Structure.) | 
|  | Discharge | 
            Calculated Discharge. The value is calculated by SetWaterLevels.
            Unit: [m^3/s]
            (Inherited from Structure.) | 
|  | DownstreamWaterLevel | 
            Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of
            SetWaterLevels
            Unit: [m]
            (Inherited from Structure.) | 
|  | ExtensionData | 
            Property used by (de)serializer, when it can not find proper target for
            a data field. Support of forward compatible data contracts. 
            (Inherited from Structure.) | 
|  | FlowArea | 
            Flow area through structure. Used by most (but not all) structures.
            (Inherited from Structure.) | 
|  | ID | 
            Structure ID
            (Inherited from Structure.) | 
|  | IDInUserUnit | 
            Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when 
            reporting errors, warnings and hints.
            (Inherited from Structure.) | 
|  | Implicit | 
            Flag to control if the structure is implicit or explicit. If the structure is explicit
            (Implicit == false) then the derivatives of the dicharge are always zero.
            Default value: true
            (Inherited from Structure.) | 
|  | InitialDischarge | 
            Initial value of the discharge.
            Default: 0
             | 
|  | InvertLevelDownstream | 
            Invert level down stream
            (Overrides StructureInvertLevelDownstream.) | 
|  | InvertLevelUpstream | 
            Invert level up stream
            (Overrides StructureInvertLevelUpstream.) | 
|  | Length | 
            Length of the structure.
            Unit: [m]
            Default value: 0m
            (Inherited from Structure.) | 
|  | Location | 
            Location property.
            (Inherited from Structure.) | 
|  | MaxDischarge | 
            Maximum discharge. The discharge (absolute value) can not be raised above this level.
            Default: double.MaxValue
             | 
|  | MaxDischargeSpeed | 
            The maximum allowed rate of change of the discharge level.
            Default: double.MaxValue
             | 
|  | Multiplicator | 
            Multiplicator or "number of structures" of this type. 
            Used for modelling more structures at the same
            location with the same geometry in one go.
            Unit: []
            Default: 1
             | 
|  | RunTimeDiagnostics | 
            The getter is used to get a list of errors.
            (Inherited from Structure.) | 
|  | SideStructureBank | 
            Bank side that side-structure is located on
            (Inherited from Structure.) If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | 
|  | SideStructureReservoir | 
            Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
            (Inherited from Structure.) | 
|  | StructureType | 
            Type of structure
            (Inherited from Structure.) | 
|  | TopoID | 
            String used to identified cross sections
            (Inherited from Structure.) | 
|  | Type | 
            Structure type, unique for each structure.
            (Overrides StructureType.) | 
|  | UpstreamWaterLevel | 
            Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
            SetWaterLevels
            Unit: [m]
            (Inherited from Structure.) | 
|  | UseControlledMaxDischarge | 
             Use the controllable maximum discharge
              Automatically set when controlling maximum discharge | 
|  | UseControlledMinDischarge | 
             Use the controllable minimum discharge
              Automatically set when controlling minimum discharge | 
|  | UseMaxDischarge | 
             Use the controllable maximum discharge level
             | 
 See Also
See Also